BT3000 PLUS Technology Advanced Random Generation Analyzer System SERVICE MANUAL P/N: MS-
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 10 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 10-1.3. LCD MODULE 8-WI
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 10 8-2.2. ARM LIQUID SENSOR & EMITTER
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 10 8-3. THE SERUM MODULE The serum module is
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 10 The new design of the sampling module inte
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 7 of 10 8-3.3. LEFT SERUM PRIMARY TUBE SENSOR BOAR
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 8 of 10 8-4. BARCODE SCANNER This is a high quality
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 9 of 10 Reagents Barcodes For the reagent system th
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 10 of 10 SERUM CHAMB
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 10 SECTION - IX ION SELECTIVE ELECTRODES (ISE) MODULE
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 10 Mixing Funnel Bubble Sensor Pi
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 10 ISE Module - View &q
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 11 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 12-2.2. VACUUM LEVEL R
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 10 FRONT VIEW ISE Mod
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 10 The ISE module accommodates the ISE electrodes, ele
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 10 The ISE controller module is a group of electroni
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 7 of 10 9-2.2. ISE CONTROLLER BOARD (15-04320-01) The cont
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 8 of 10 9-3. COMMONLY ASKED ISE QUESTIONS The question and
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 9 of 10 COMMONLY ASKED ISE QUESTIONS (contd.) Can the analy
Section - IX ISE Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 10 of 10 9-4. ISE TROUBLE-SHOOTING BT3000 PLUS (Quick Refe
Section - X Computer Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 sur 5 SECTION - X COMPUTER BOX ASSEMBLY
Section - X Computer Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 sur 5 10-1. ELECTRONICS MODULE 10-1.1. COMPUTER BOX
Section - X Computer Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 sur 5 Automatic turning off of the fan: during this p
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 12 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 13-3.1. REAGENT CONTRO
Section - X Computer Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 sur 5 10-1.5. MOTHERBOARD LAYOUT CONTENTS
Section - X Computer Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 sur 5 External Connectors 1 PS2KBMS PS/2 Mouse Port
Section - XI Power Supply BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 2 SECTION - XI POWER SUPPLY AC/DC MODULE 11-1.
Section - XI Power Supply BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 2 11-1.2. POWER FACTOR CORRECTION (PFC) Certain ap
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 1 of 26 SECTION XII VACUUM PUMP SYSTEM P/N 06-0516
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 2 of 26 The liquids aspirated by the pumps from t
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 3 of 26 12-1.2. DESCRIPTION OF THE BOARD 15-0508
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 4 of 26 The MOSFET Q1 is used for supplying or swi
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 5 of 26 If the red LED (DL3) lights up then this i
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 6 of 26 NOTE: The liquid level sensor is magnetica
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 13 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 14-5. VERIFICATION OF
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 7 of 26 12-1.5. MAINTENANCE AND CARE This compa
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 8 of 26 12-1.7. SPA
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 9 of 26 VACUUM PUMP SYSTEM P/N 662.0788/C/D/E/F (O
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 10 of 26 The suction unit cabinet accommodates two
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 11 of 26 12-2.5. INSTALLATION PROTOCOL Refer to F
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 12 of 26 12-2.7. CARE AND MAINTENANCE For this ca
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 13 of 26 12-2.9. FILTER REPLACEMENT 1) Disconnec
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 14 of 26 12-2.11. VACUUM REGULATION PROCEDURE The
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 15 of 26 The liquid level sensor controls the peri
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 16 of 26 The various gates of the integrated U3 cir
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 14 of 15 BT3000 PLUS - TABLE OF CONTENTS SCHEMATICS AND DIAGRAMS ELECTRONICS SYSTEM
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 17 of 26 12-2.14. Trouble-Shooting Guide SYMPTOMS
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 18 of 26 12-2.15. SPARE PARTS FOR REPAIR AND MAINT
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 19 of 26 12-2.16. TECHNICAL SPECIFICATIONS Techn
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 20 of 26 12-2.17. CLEANING OF THE HYDROPHOBIC FILT
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 21 of 26 Vacuum Pu
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 22 of 26 SPARE
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 23 of 26 WASTE C
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 24 of 26 CONT
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 25 of 26
Section - XII Vacuum Pump System BT3000 PLUS Rev. 0, Soft Ver. 8, Page 26 of 26
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 15 of 15 BT 3000 PLUS - TABLE OF CONTENTS VACUUM PUMP SYSTEM P/N 06-05161-01/02/03
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 10 SECTION - XIII MEASUREMENTS &a
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 10 Specifications are valid for t
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 10 Cuvette 1st Chan. 2nd chan.
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 10 13-2.1. CUVETTE TEMP. CALIBRA
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 10 Select "Temperature Cali
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 10 13-3.2. REAGENT CONTROLLER BO
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 7 of 10 13-4.2. BARCODE - MECHANICAL
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 8 of 10 13-5.1. ISE BUBBLE SENSOR CAL
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 9 of 10 13-5.2. ISE HYDRAULIC CIRCUIT
Section - XIII Measurements and Calibrations BT3000 PLUS Rev. 0, Soft Ver. 8 Page 10 of 10 There are two primary tube se
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 1 of 12 SECTION A WARRANTY CONDITIONS • Biote
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 15 SECTION - XIV TROUBLE - SHOOTING 14-1. INT
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 15 14-1.2. TROUBLE-SHOOTING REAGENT CHAMBER TEM
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 15 14-1.4. TROUBLE-SHOOTING POWER UP PROBLEMS PO
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 15 14-1.6. TROUBLE-SHOOTING RESET ERRORS Reset
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 15 Reset Errors: Serum Plate/Reagent Tray/Dilu
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 15 Reset Errors: Serum Plate/Reagent Tray/Dilu
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 7 of 15 14-2. COMPUTER MODULE TROUBLE-SHOOTING The
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 8 of 15 COMPUTER MODULE TROUBLE SHOOTING SYMPTOMS C
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 9 of 15 BOOTSTRAP - COMPUTER MODULE TROUBLE SHOOTING
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 10 of 15 BOOTSTRAP - COMPUTER MODULE TROUBLE SHOOTING
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 2 of 12 From: To: Technical Assistanc
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 11 of 15 To verify the photometric instability (relev
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 12 of 15 14-6. ISE TROUBLESHOOTING If the routine mai
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 13 of 15 b) OBSTRUCTIONS CAUSED BY PROTEINS IN ELECTR
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 14 of 15 NOTICE It is often possible to extend
Section - XIV Troubleshooting BT3000 PLUS Rev. 0, Soft Ver. 8 Page 15 of 15
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 10 SECTION XV BT 3000 PLUS SPARE PARTS FOR REPAIR AND MA
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 10 WASHING MODULE PART NO. DESCRIPTION 07-04850-01
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 10 15-2. REAGENT/REFRIGERATION SYSTEM SPARE PART NO. D
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 10 PART NO. DESCRIPTION 11-05044-01 WASHING FUNNEL 11-0
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 10 15-5. ISE MODULE SPARE PARTS PART NO. DESCRIPTION 0
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 3 of 12 POTENTIAL RISKS DURING OPERATION AND MA
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 10 15-6. COMPUTER BOX PART NO. DESCRIPTION 06-04379-0
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 7 of 10 15-7. CONSUMABLES PART NO. DESCRIPTION 392 SURFACTA
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 8 of 10 15-8. ELECTRONICS HARDWARE PART NO. DESCRIPTION 08-0
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 9 of 10 VACUUM PUMP SYSTEM P/N 662.0788/C/D/E/F (OBSOLETE) PA
Section XV Spare Parts BT3000 PLUS Rev. 0, Soft Ver. 8 Page 10 of 10 15-10. ORDERING INFORMATION Please contact Biotecnic
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 4 of 12 WARNINGS ALTHOUGH THE BT3000 PLUS ANAL
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 2 of 15 MANUAL REVISION RECORD This record page is for recording revisions to you
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 5 of 12 15. IF THE SYSTEM IS NOT OPERATING PRO
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 6 of 12 33. DO NOT PLACE THE SYSTEM ON AN UNST
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 7 of 12 DANGER a) TO AVOID ACCID
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 8 of 12 CONFORMANCE IMPORTANT NOTICE -
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 9 of 12 THE COMPANY PROFILE Biotecnica was f
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 10 of 12 PACKING / UNPACKING THE ANALYZER
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 11 of 12 Verify upon receipt of the BT3000 PLUS
Section A Warnings, Warranty, Unpacking BT3000 PLUS Rev.0, Soft Ver. 8 Page 12 of 12 ♦ VERIFYING EVENTUAL DAMAGES OCCURRED
Section - I Introduction BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 3 SECTION - I INTRODUCTION - BT3000 PLUS The BT3000
Section - I Introduction BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 3 1-3. PHASE 2: Placement of Samples and Reagents
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 3 of 15 This Page is intentionally left blank
Section - I Introduction BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 3 1-6. PHASE 5 - Reading Cycle In this phase, the
Section - II Technical Specs BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 6 SECTION - II TECHNICAL SPECIFICATIONS NOTE: Spe
Section - II Technical Specs BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 6 2-4. PERFORMANCE & TECHNICAL SPECS Operating
Section - II Technical Specs BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 6 2-4.2. VOLUMES WORKING SOLUTIONS Clinical Chem
Section - II Technical Specs BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 6 2-4.4. “UTILITY” EXECUTION TIMES Wash & Fi
Section - II Technical Specs BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 6 2-7. REAGENT REFRIGERATION The purpose of reage
Section - II Technical Specs BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 6 2-10. PHOTOMETER TUNGSTEN HALOGEN LAMP This la
Section - III Electronics BT3000 PLUS Rev.0, Soft Ver. 8 Page 1 of 5 SECTION - III ELECTRONICS 3-1. Top View of the BT
Section - III Electronics BT3000 PLUS Rev.0, Soft Ver. 8 Page 2 of 5 3-2. Analyzer Structure The analyzer structure is co
Section - III Electronics BT3000 PLUS Rev.0, Soft Ver. 8 Page 3 of 5 3-3.2. Reading Station The reading station is compri
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 4 of 15 BT 3000 PLUS - TABLE OF CONTENTS SECTION A • WARRANTY CONDITIONS • INST
Section - III Electronics BT3000 PLUS Rev.0, Soft Ver. 8 Page 4 of 5 3-4. System Electronics The electronics of the an
Section - III Electronics BT3000 PLUS Rev.0, Soft Ver. 8 Page 5 of 5 3-5. Example of the I2C-BUS Configuration The I2C-
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 1 of 15 SECTION - IV SOFTWARE Important Notice: Any modificat
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 2 of 15 ► Send type of serum...
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 3 of 15 4-3. RESULTS RECEPTION There are three commands for rec
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 4 of 15 4-4. CALCULATION OF CHECK-SUM: This procedure calculat
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 5 of 15 4-6. VARIABLE SERIAL PROTOCOL Introduction The var
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 6 of 15 Error Code Description 18 The patient is not to be re
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 7 of 15 There are also variables for direct uses, which allow
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 8 of 15 Set: Identifies the beginning and the end of the group
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 5 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 2-5. FUNCTIONAL LIMITS...
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 9 of 15 14 Incorrect identifier in the SET command. a) The tex
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 10 of 15 (4) Identifies Clinical Chemistry, ISE Module or Relat
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 11 of 15 (3) Identifies Serum or Urine (Select only one of thes
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 12 of 15 ‘Y’ : Clone ‘NOCLONE’ : Normal ‘CLONE’ : Clone (8)
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 13 of 15 SCRIPT EXAMPLES The examples outlined here are the t
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 14 of 15 The following examples are the transformation in scrip
Section - IV Software BT3000 PLUS Rev.0, Soft Ver. 8 Page 15 of 15 For example the Character EOT - value 4 - will be show
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 sur 22 SECTION - V REPAIR OR REPLACEMENT OF VA
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 sur 22 5-1. ACCESS TO VARIOUS MODULES - IN
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 sur 22 Do not tighten the new sam
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 6 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 4-7. SERIAL COMMUNICATIO
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 sur 22 5) Move CCW (counterclockwise) and low
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 sur 22 IMPORTANT NOTICE: Mechanical calibratio
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 sur 22 7) Place the cover on the arm head
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 7 sur 22 Final testing: After terminating the in
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 8 sur 22 5-2.2. SAMPLING TUBE WITH NEEDLE HOLDE
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 9 sur 22 6) Correctly install the new "S
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 10 sur 22 5-3. REPAIR OR REPLACEMENT OF THE REA
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 11 sur 22 Unsolder the leads of the defective Pe
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 12 sur 22 The temperature sensor is housed in a r
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 13 sur 22 5-4.2. REPLACEMENT OF T
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 7 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. Fig.5-8 ARM HEAD (TOP VI
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 14 sur 22 Disconnect the input power before se
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 15 sur 22
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 16 sur 22 SIX MONTH MAINTENANCE KIT (P/N. 11-052
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 17 sur 22 5-4.5. REPLACEMENT OF THE WASHING PIS
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 18 sur 22 When replacing the cuvette wheel, posi
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 19 sur 22 All of the connections to the external
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 20 sur 22 5-5.2. 8-WIRE ANALOGUE RESISTIVE TOUC
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 21 sur 22
Section - V Repair or Replacement BT3000 PLUS Rev. 0, Soft Ver. 8 Page 22 sur 22 Figure 5-26
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 12 SECTION - VI READING STATION 6-1. GENERAL Th
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 8 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 6-9.1. TECHNICAL SPECIFI
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 12 6-2. PHOTOMETER MODULE
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 12 The reference channel provides stability to th
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 12 The lamp efficiency is controlled by the analy
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 12 6-4. DILUTER AND WASHER MODULE T
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 12 4) TUBING & CONNECTORS: Most of the in
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 7 of 12 6-4.1. DILUTER OPERATING PRINCIPLE
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 8 of 12 6-5. ELECTRONICS FOR THE REA
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 9 of 12 The same µP552 utilizes two analog inputs for
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 10 of 12 6-8. INTERFACE BOARD (15-04270-01) The ISE s
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 11 of 12 The calibration of each channel is performed
INDEX - BT3000 PLUS REV. 0, Soft Ver. 8 Page 9 of 15 BT3000 PLUS - TABLE OF CONTENTS PARA. TITLE SECT. 8-3.1. SERUM PLATE CONTR
Section - VI Reading Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 12 of 12 6-9.1. TECHNICAL SPECIFICATIONS OF THE PHOTOM
Section - VII Reagent Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 6 SECTION VII REAGENT SYSTEM 7-1. GENERAL The re
Section - VII Reagent Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 6 The gate P0.7 of µC U3 sends the command bit o
Section - VII Reagent Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 6 7-3. REAGENT PLATE CONTROLLER - 15-04313-03
Section - VII Reagent Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 4 of 6 7-5. REAGENT & SERUM BARCODES The availa
Section - VII Reagent Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 5 of 6
Section - VII Reagent Module BT3000 PLUS Rev. 0, Soft Ver. 8 Page 6 of 6 REAGENT
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 1 of 10 SECTION - VIII SAMPLING STATION 8-1. GE
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 2 of 10 Both arms have a built-in facility for the
Section - VIII Sampling Station BT3000 PLUS Rev. 0, Soft Ver. 8 Page 3 of 10 8-2.1. ARM CONTROLLER BOARD (15-04765-01)
Comentários a estes Manuais